Sign In | Join Free | My frbiz.com
China SUZHOU TISCHBEIN ELEVATOR CO., LTD logo
SUZHOU TISCHBEIN ELEVATOR CO., LTD
TISCHBEIN ELEVATOR, TIED TO SAFETY!
Site Member

2 Years

Home > Hospital Elevator >

1000kg 1250kg 1600kg Medical Hospital Elevator 0.5m/s 1.0m/s 1.5m/s With Disabled COP For Disabled People

SUZHOU TISCHBEIN ELEVATOR CO., LTD

1000kg 1250kg 1600kg Medical Hospital Elevator 0.5m/s 1.0m/s 1.5m/s With Disabled COP For Disabled People

  • 1
  • 2

Brand Name : TISCHBEIN

Model Number : TSB-10

Certification : ISO CE

MOQ : 1 Unit

Price : US$10000-US$30000

Delivery Time : 25 DAYS

Packaging Details : WOODEN BOX

Usage : Hospital Medical care center Emergency Medical Center

Elevator type : Large Space Stainless Steel of Hospital Elevator for hospital or emergency medical center

Rated speed : 0.5m/s 1.0m/s 1.5m/s

Product name : Hospital elevator

Control : traction VVVF

Application : hospital or emergency medical center

Material : Stainless Steel 304, Hairline Stainless Steel, Stainless Steel(Hairline/Mirror/Painted/Etching)/Rose Gold/Titanium, Mirror etched

Load capacity : 1000kg 1250kg 1500kg 1600kg 2000kg

Keywords : VVVF Hospital Elevator Bed elevator Machine room hospital Elevator

Traction machine : Geared machine

Control system : VVVF Elevator Control System, VVVF Monarch Nice3000, VVVF

Warranty : 18 month after delivery

Machine room : Above the shaft or MRL

Contact Now

1000kg 1250kg 1600kg Medical Hospital Elevator 0.5m/s 1.0m/s 1.5m/s with Disabled COP For Disabled People

1.0m/s HOSPITAL ELEVATOR BED ELEVATOR Medical Elevator with diabled COP usded for hospital, medical care center

TISCHBEIN TSB-10 series hospital/bed elevator is appliable for the places of hospital, emergency medical center, residential area, etc. Life safety comes first. Each time of speeding up of elevator is to race against life; each stable operation of TISCHBEIN elevator is respect on life; each time of reform in elevator is responsible for life. We set out from heart, and what we do is much more than what you can imagine.

1. Main Parameters

Model NO.
TSB-10
Elevator Type
Hospital Elevator Medical Elevator
Load capacity
1000kg, 1150kg, 1250kg, 1350kg, 1600kg, 2000kg
Traction machine
Permanent Magnet Sychronous Gearless Traction Machine
Speed
1.0m/s 1.5m/s 1.75m/s 2.0m/s 4m/s
Elevator Door
Center Opening Door Telescopic Opening Single Door Through Door
Certification
ISO CE
Door Protection
Full Range of Infrared Light Curtain Protection
Travel Height
3.2m - 150m
Application
Office Building Hotel Resideitial Building
Shape
Square with 3 Sides Glass Wall or Semi Round Glass Wall or Full Round Glass Wall
Material
Hairline Stainless Steel Mirror Stainless steel Etching Stainless Steel
Feature
Low Noise
Drive
VVVF
Color Standard Series
Customized
Communication Mode
Serial Parallel
Energy Saving Technology
Energy Feedback Technology
Executed Code
EN81 EN115
Brand Name
TISCHBEIN
Drive Mode
Collective Selective Control
Transport Package
Standard Export Package
Warranty Period
One Year
Trademark
TISCHBEIN
Production Lead Time
25 Days
HS Code
8428101090
Production Capacity
5000 Units Per Year

1000kg 1250kg 1600kg Medical Hospital Elevator 0.5m/s 1.0m/s 1.5m/s With Disabled COP For Disabled People1000kg 1250kg 1600kg Medical Hospital Elevator 0.5m/s 1.0m/s 1.5m/s With Disabled COP For Disabled People1000kg 1250kg 1600kg Medical Hospital Elevator 0.5m/s 1.0m/s 1.5m/s With Disabled COP For Disabled People

2. Special Features and Configurations:

Anti-nuisance operation

In case of substantial difference between the number of calls registered on the car operating panel and actual load in the elevator, the elevator prevents unnecessary operation by cancelling all registered calls when it arrives at the nearest floor.

Car call cancellation

Allows cancellation of an incorrectly registered car call. If you push a wrong floor button in the car, you can cancel it by pressing the same button one more time

Automatic turnoff of car light and fan

Car illumination and fan a returned off automatically in case there is no hall call or car call to save energy.

Bypass operation (80%)

If the actual load comes to more than 80%of the allowable maximum load, the elevator will not react to the calling signals from other passing floors

Overload (110%of rated load) holdings top

When the load of passengers exceeds the maximum capacity, a buzzer sounds and the elevator remains stopped at that floor. When the passengers get off, the buzzer will stop. Consequently, elevator doors will close and operation continues.

Anti-hall button jamming

If landing door would not have closed by a hall button's jamming and it is caused car can't start. Then, the floor will close in force by the command from controller so that the car service next calls.

Door reopen control

While the car door is closing, if a door reopen signal is occurred the door will be reopened immediately and after specified time expired the door will again close.

Car door safety edge

This device enables the doors to return to the fully open position, should the door encounter a person or obstacle while closing.

Automatic adjustment of door time

Door closing time can be adjusted in order to improve the efficiency Micro Leveling. An automatic two-way leveling device is provided to maintain the elevator car level with the landing, regardless of elevator load or direction travel

Back-up operation

ln normal operation, if the serial communication between the controller and it's terminal board have something malfunction, the car mode is changed to a “back-Up" mode automatically, then the car checks itself by servicing every even floors and every odd floors until the car returns normal condition. By this operation, even though the car has something malfunction, passengers can be offered a limited service without shout down.

Safety Drive operation

During normal operation, a malfunction is occurred suddenly but it's not serious, in this case, if the car is not in a door zone, then the car starts to run to the nearest floor in slow speed. After stop at the nearest floor, the care remains stop with door fully open and "Out

of Service" lamp. If the car condition is possible to return a normal condition itself then, the car can service normal operation again.

1000kg 1250kg 1600kg Medical Hospital Elevator 0.5m/s 1.0m/s 1.5m/s With Disabled COP For Disabled People1000kg 1250kg 1600kg Medical Hospital Elevator 0.5m/s 1.0m/s 1.5m/s With Disabled COP For Disabled People

TISCHBEIN ELEVATOR, TIED TO SAFETY. Welcome to contact us!


Product Tags:

1500kg Hospital Elevator Through Door Opening

      

1250kg Hospital Elevator

      

1.5m/s Hospital Bed Elevator

      
China 1000kg 1250kg 1600kg Medical Hospital Elevator 0.5m/s 1.0m/s 1.5m/s With Disabled COP For Disabled People wholesale

1000kg 1250kg 1600kg Medical Hospital Elevator 0.5m/s 1.0m/s 1.5m/s With Disabled COP For Disabled People Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: SUZHOU TISCHBEIN ELEVATOR CO., LTD
*Subject:
*Message:
Characters Remaining: (0/3000)
 

Friendly Links: www.everychina.com

Home| Products| Suppliers| Quality Suppliers| Site Map |About Us |Help

Copyright © 2009 - 2024 frbiz.com. All rights reserved.